{"id":446,"date":"2025-01-15T14:10:41","date_gmt":"2025-01-15T21:10:41","guid":{"rendered":"https:\/\/faculty.engineering.asu.edu\/balanis\/?page_id=446"},"modified":"2025-01-21T09:38:43","modified_gmt":"2025-01-21T16:38:43","slug":"emac","status":"publish","type":"page","link":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/","title":{"rendered":"EMAC"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"411\" src=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif\" alt=\"\" class=\"wp-image-447\" style=\"width:763px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div  class=\"uds-blockquote accent-black\" style=\"\">\n\t<svg title=\"Open quote\" role=\"presentation\" viewBox=\"0 0 302.87 245.82\">\n\t<path d=\"M113.61,245.82H0V164.56q0-49.34,8.69-77.83T40.84,35.58Q64.29,12.95,100.67,0l22.24,46.9q-34,11.33-48.72,31.54T58.63,132.21h55Zm180,0H180V164.56q0-49.74,8.7-78T221,35.58Q244.65,12.95,280.63,0l22.24,46.9q-34,11.33-48.72,31.54t-15.57,53.77h55Z\"\/>\n\t<\/svg><blockquote><p>Nothing is too wonderful to be true if it be consistent with the laws of nature, and in such things as these, experiment is the best test of such consistancy.<\/p>\n<div class=\"citation\"><div class=\"citation-content\"><cite class=\"name\">Michael Faraday <\/cite><cite class=\"description\"><\/cite><\/div><\/div><\/blockquote><\/div><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">The EMAC Facility<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p><strong>The ElectroMagnetic Anechoic Chamber (EMAC) is a 2,200 square foot facility that supports the research of faculty and graduate students by providing precision antenna and radar cross section measurements. In addition, the facility is a test-bed for a unique design in Compact Antenna Test Ranges (CATR).<\/strong><\/p>\n\n\n\n<p><strong>With inside dimensions of 51 ft. (15.5m) by 26 ft. (7.9m) by 18 ft. (5.5m), ASU&#8217;s EMAC facility has one of the largest university-based anechoic chambers in the United States. The shielded room is lined with microwave absorbing material to greatly reduce the reflections, or echoes, of the test signals inside. This controlled environment simulates the conditions of &#8220;free space&#8221; that are suitable for testing antennas and scattering targets.<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"196\" height=\"359\" src=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/chamber.gif\" alt=\"\" class=\"wp-image-452\" style=\"width:375px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">The Single-Plane Collimating Range<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"518\" height=\"518\" src=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/renderingi.gif\" alt=\"\" class=\"wp-image-454\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p><strong>The March Microwave-designed Single-Plane Collimating Range (SPCR) is a curved, highly polished metal reflector that reshapes the spherical phasefronts produced by the system&#8217;s feed into high-quality cylindrical wavefronts in the test region. Cylindrical wave measurements are then transformed into the desired plane wave results via computer software. The primary advantage of the SPCR over conventional, fully collimating CATRs is a much larger quiet zone in the horizontal plane. ASU has the distinction of being the first to implement this cylindrical wave range configuration.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Measurement Capabilities<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>The SPCR reflector is specified by the manufacturer to operate from 2 GHz to 100 GHz. The EMAC facility currently has linearly polarized feed horns which cover frequencies from 500 MHz to 18 GHz.<\/strong><\/p>\n\n\n\n<p><strong>Test targets are oriented with an Orbit azimuth-over-elevation positioner which is rated at 2500 lbs maximum vertical load and 2500 ft-lbs maximum bending moment. The positioner is driven with a Scientific Atlanta 4139 positioner controller.<\/strong><\/p>\n\n\n\n<p><strong>The instrumentation at the EMAC facility is based on the HP8510C Vector Network Analyzer. Consequently, in addition to radiation and scattering patterns, all S-parameter based measurements can be performed. The frequency range of the instrumentation is from 10 MHz to 20 GHz.<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"820\" height=\"539\" src=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2024\/11\/image-18.png\" alt=\"\" class=\"wp-image-113\" srcset=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2024\/11\/image-18.png 820w, https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2024\/11\/image-18-500x329.png 500w\" sizes=\"auto, (max-width: 820px) 100vw, 820px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p class=\"mb-2\">The EMAC Facility The ElectroMagnetic Anechoic Chamber (EMAC) is a 2,200 square foot facility that supports the research of faculty and graduate students by providing precision antenna and radar cross section measurements. In addition, the facility is a test-bed for a unique design in Compact Antenna Test Ranges (CATR). With inside dimensions of 51 ft&#8230;.<\/p>\n","protected":false},"author":443,"featured_media":0,"parent":0,"menu_order":7,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-446","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>EMAC - Balanis&#039; Corner<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EMAC - Balanis&#039; Corner\" \/>\n<meta property=\"og:description\" content=\"The EMAC Facility The ElectroMagnetic Anechoic Chamber (EMAC) is a 2,200 square foot facility that supports the research of faculty and graduate students by providing precision antenna and radar cross section measurements. In addition, the facility is a test-bed for a unique design in Compact Antenna Test Ranges (CATR). With inside dimensions of 51 ft....\" \/>\n<meta property=\"og:url\" content=\"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/\" \/>\n<meta property=\"og:site_name\" content=\"Balanis&#039; Corner\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-21T16:38:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"411\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/\",\"url\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/\",\"name\":\"EMAC - Balanis&#039; Corner\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/wp-content\\\/uploads\\\/sites\\\/220\\\/2025\\\/01\\\/emac2.gif\",\"datePublished\":\"2025-01-15T21:10:41+00:00\",\"dateModified\":\"2025-01-21T16:38:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/#primaryimage\",\"url\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/wp-content\\\/uploads\\\/sites\\\/220\\\/2025\\\/01\\\/emac2.gif\",\"contentUrl\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/wp-content\\\/uploads\\\/sites\\\/220\\\/2025\\\/01\\\/emac2.gif\",\"width\":640,\"height\":411},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/emac\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EMAC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/#website\",\"url\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/\",\"name\":\"Balanis&#039; Corner\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/faculty.engineering.asu.edu\\\/balanis\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EMAC - Balanis&#039; Corner","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/","og_locale":"en_US","og_type":"article","og_title":"EMAC - Balanis&#039; Corner","og_description":"The EMAC Facility The ElectroMagnetic Anechoic Chamber (EMAC) is a 2,200 square foot facility that supports the research of faculty and graduate students by providing precision antenna and radar cross section measurements. In addition, the facility is a test-bed for a unique design in Compact Antenna Test Ranges (CATR). With inside dimensions of 51 ft....","og_url":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/","og_site_name":"Balanis&#039; Corner","article_modified_time":"2025-01-21T16:38:43+00:00","og_image":[{"width":640,"height":411,"url":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif","type":"image\/gif"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/","url":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/","name":"EMAC - Balanis&#039; Corner","isPartOf":{"@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/#website"},"primaryImageOfPage":{"@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/#primaryimage"},"image":{"@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/#primaryimage"},"thumbnailUrl":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif","datePublished":"2025-01-15T21:10:41+00:00","dateModified":"2025-01-21T16:38:43+00:00","breadcrumb":{"@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/#primaryimage","url":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif","contentUrl":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-content\/uploads\/sites\/220\/2025\/01\/emac2.gif","width":640,"height":411},{"@type":"BreadcrumbList","@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/emac\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/faculty.engineering.asu.edu\/balanis\/"},{"@type":"ListItem","position":2,"name":"EMAC"}]},{"@type":"WebSite","@id":"https:\/\/faculty.engineering.asu.edu\/balanis\/#website","url":"https:\/\/faculty.engineering.asu.edu\/balanis\/","name":"Balanis&#039; Corner","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/faculty.engineering.asu.edu\/balanis\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/pages\/446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/users\/443"}],"replies":[{"embeddable":true,"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/comments?post=446"}],"version-history":[{"count":0,"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/pages\/446\/revisions"}],"wp:attachment":[{"href":"https:\/\/faculty.engineering.asu.edu\/balanis\/wp-json\/wp\/v2\/media?parent=446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}